Security and NIS2
We are in your supply chain. And built for it.
A gateway in the OT network has to pass a supply chain assessment. FactoryNebula is designed for that: no internet needed, read-only by default, roles, an audit log of every write action and remote management without an open port.

Gateway · system
Example
Outbound connection
None
Remote management
Closed
Write actions today
3 · in audit log
Today in the gateway
Security built into the design
Not added afterwards, but the foundation on which every module is built.
No outbound connection needed
The gateway works entirely within the OT network. Nothing is loaded from the internet, not even fonts or icons.
Encrypted access
One entry point with HTTPS and client certificates as the outer ring. Every module can only be reached via that entry point.
Roles
From viewing, operating and configuring to administration. Platform administration is a role that cannot be assigned via the screen.
Read-only by default
Writing is enabled per command, with limits that the gateway enforces itself.
Audit log
Every write attempt, including rejected ones: who, what, where to, old and new value and the result.
Two-factor authentication
A code from an authenticator app. Works without internet, unlike text messages or email.
Self-reporting
The gateway itself reports which versions, services and settings it has.
Warnings
The system screen warns you if a module is too widely accessible or allows anonymous access.

Safe writing
Reading is the default, writing is a deliberate choice
A PLC is physical. That is why fixed rules apply before a value ever goes to a machine.
- A command has a name, not an address; the address stays in the gateway
- Limits (minimum, maximum, allowed values) are enforced in the gateway, not by the caller
- A test mode checks everything without writing
- Optionally an explicit confirmation on screen
- Every attempt in the audit log

Remote management
No open port, a tunnel that closes itself
Help with a fault sometimes requires access. An open port in a factory network is out of the question. That is why the gateway itself builds an outbound, encrypted connection.
- Closed by default; nobody can start from outside
- Mandatory expiry time: one hour by default, eight at most
- Does not come back by itself after a restart
- Visible on every screen as long as it is open
- Only the platform administrator may open it
NIS2, honest from the start
Software doesn’t make you compliant. It does make you able to prove it.
NIS2 is an EU directive for organisations, not a quality mark for software. Anyone who promises that a product makes you compliant is selling something. What FactoryNebula does deliver:
- A gateway that passes your supply chain assessment: we are in your supply chain, and we take that seriously
- The evidence the directive asks for: who did what, when, and with what result
- Locally stored records, even if the network to the office drops out
- Detection that helps you say within 24 hours what was going on
Detection
Threat detection on the OT network
A factory network is small, static and predictable. And the gateway already knows the ground truth: which machines there are, which protocol they speak and at which address. That makes detection possible without a learning period.
- A baseline that is already in the configuration
- Alerts with meaning: not “unknown traffic”, but “something is talking to a PLC that is not in the configuration”
- Alerts in the health screen and an incident file
- Requires a mirror port on the switch; we arrange that together with your network administrator

For engineers
Network analysis without PLC source code
A tool that passively listens in on Siemens S7 traffic: which addresses does an HMI or SCADA read and write? Useful when there is no source code for the PLC. Addresses found are suggested as variables.
Frequently asked questions
About security
Want to go through the architecture with your IT team? Get in touch.
Does FactoryNebula make us NIS2 compliant?
No, and no product can. NIS2 is about your organisation. FactoryNebula helps you meet your obligations with roles, audit logging and locally stored records, and is built to pass your supply chain assessment.
Which ports need to be open?
From outside to the gateway only HTTPS. From the gateway to the machines the protocol ports, such as 102 (Siemens S7), 502 (Modbus), 4840 (OPC UA), 8193 (FANUC), 19000 (Heidenhain) and 44818 (EtherNet/IP). Nothing outbound is required.
How do you access the gateway remotely?
Only via a tunnel that the gateway itself builds outbound, when a platform administrator deliberately does so. With an expiry time, and visible as long as it is open.
Where are passwords and users stored?
Only on the gateway itself. They are not included in an update and never leave the gateway.
What if the gateway breaks down?
The configuration is an exportable file. A replacement gateway gets the same software and the exported configuration.
Combine with
Works together with
Connecting machines
Siemens, FANUC, Heidenhain, Allen-Bradley, OPC UA, Modbus and peripherals. No PLC programming, in the same form for every brand.
ERP and CAM integration
Orders as a work list per machine, the drawing with the item and the completion report back to the office.
Workflows
If this, then that, without programming. Respond to a signal, send a command or report an order complete.
Discuss your architecture with us
We are happy to go through with your IT and OT team how FactoryNebula fits into your network.