Troubleshooting the way you are used to.

See what a machine is doing, put signals side by side and look back at what happened just before a breakdown. Without software on a laptop, without touching the PLC and for every brand.

Screen with trends and dashboards

Trend · Press 01

Example

Pressure

2.8 bar

Pump on

On

Valve open

Closed

What you do with it

From live value to looking back

The data analyser works with everything the gateway reads. You view a Siemens value in exactly the same way as an OPC UA value or a FANUC counter.

Live

The current values of the signals you choose.

Trend

Up to ten windows, digital lanes for bits, measuring cursors A and B with the difference between them, and an X/Y view.

History

Record signals continuously on the gateway, read them back quickly and export as CSV or image.

Limits

A limit with hysteresis on a signal. When it is exceeded, a notification goes out that a workflow can pick up.

Triggered recording

Continuously keep the last few minutes and only record when the alarm comes, including what happened before it.

Statistics and correlation

Make relationships between signals visible.

Share recordings

Forward a recording to a colleague or the machine builder.

In practice

What did the pressure do in the minute before the alarm?

A machine occasionally fails with a pressure alarm. You want to see what pressure, pump and valve did in the minutes before.

01

Find signals

In the browser, point to Pressure, Pump on and Valve open and turn them into measurements.

02

Record

Enable history for the three signals and wait until the fault occurs again.

03

Look back

Cursor A at the moment the pump switched off, cursor B on the alarm: you see the time and pressure difference.

04

Know earlier from now on

Set a limit, for example below 2.5 bar, and let a workflow warn maintenance.

Milling head of a CNC machine

For every brand

One tool instead of ten

No separate software per brand on a laptop, and no connection to the PLC needed to look. The analyser works on the gateway and reads what is already coming in there.

  • Works in the browser, without installation
  • The same steps for every protocol
  • A limit notification can start a workflow directly
  • Export for the technician or the machine builder

Combine with workflows

Frequently asked questions

About the data analyser

Want to know more? All frequently asked questions.

Does software need to be installed on a laptop?

No. The data analyser runs on the gateway and works in the browser.

Does it work with our brands?

With everything the gateway reads: Siemens, OPC UA, Modbus, Allen-Bradley, FANUC, Heidenhain and peripherals. The steps are the same for every brand.

How long is history kept?

You set that per signal, optionally with a minimum interval or a deadband, so you only keep what is meaningful.

Combine with

Works together with

Workflows

If this, then that, without programming. Respond to a signal, send a command or report an order complete.

About workflows

Downtime analysis

Every stop recorded automatically with start and duration. See which machines stop most often and for longest.

About downtime analysis

Connecting machines

Siemens, FANUC, Heidenhain, Allen-Bradley, OPC UA, Modbus and peripherals. No PLC programming, in the same form for every brand.

All connectors

Find your next breakdown faster

In a personal demo we show how to use the data analyser to look back at what happened just before a breakdown.