Reading a Siemens S7 PLC: what needs to be set on the PLC side?
What to set in the PLC to read an S7-1200 or S7-1500 over the network, without changing the PLC program. With the most common mistakes.
Siemens S7
FactoryNebula reads values from Siemens S7-300, S7-400, S7-1200 and S7-1500 over the network, continuously or on a trigger, and puts them on the bus and in the database. For reading, nothing needs to change in the PLC program.

Siemens S7 · live
Example
Press 01 · Part counter
1.532
Press 01 · Temperature
71,8 °C
What it does
Every machine arrives on the bus in the same way. Everything built on top of it, such as dashboards, OEE and workflows, therefore works for every brand.
A read rate and destination of its own for each group of variables: the temperature every second to the bus, the order number once a minute to the database.
Read once as soon as a message arrives, for example “order complete”. That produces a report per product, also as a CSV file, without PLC programming.
Import variables in one go from an export of the PLC software, instead of typing them in one by one.
A network analysis passively listens in on which addresses an HMI or SCADA reads and writes, and suggests them as variables.
Adding a device means an IP address, rack and slot. You choose the rest in the connector’s web page.
On the machine side
For reading, nothing needs to change in the machine program. You arrange this in advance.
Specifications
Not for reading. On an S7-1200 or S7-1500, PUT/GET access must be enabled and the data blocks you read must be without optimised access. Those are settings, not program changes.
Usually PUT/GET access is disabled. In the CPU settings, enable the option Permit access with PUT/GET communication and download the configuration to the PLC again.
Then optimised block access is probably enabled. Turn that attribute off for the data block, so the variables get fixed offsets.
Yes, per command. You define which value may go to which address, within which limits and by whom. Every attempt goes into the audit log, and a test mode checks everything without writing.
Further reading
What to set in the PLC to read an S7-1200 or S7-1500 over the network, without changing the PLC program. With the most common mistakes.
A PLC is physical. Five rules for writing values to a machine safely, without a workflow or a typo being able to upset the machine.
Why every machine should get a fixed place in one structure for the whole factory, and why that makes integrations so much simpler.
More connectors
Any OPC UA server in a PLC, CNC or SCADA, with browser and certificates.
Modbus TCP and RTU: drives, energy meters, simple PLCs and sensors.
Read ControlLogix and CompactLogix by tag name, with tag browser.
Status, program, part counter and alarms of FANUC controls, with network scan.
iTNC 530, TNC 640 and related: status, program, tool, axes and PLC values.
Every read of a SICK Lector on the bus: QR, DataMatrix and barcodes.
Status of Linx coding printers, and loading messages such as lot number or date.
In a personal demo we show how a machine gets into FactoryNebula, and what is needed on the machine side.