OPC UA and Modbus: two ways to read machine data
Two widely used protocols for getting data out of machines, and when you will come across each. Plus: what if a machine has neither?
OPC UA
Many PLCs, CNCs and SCADA systems offer their data via OPC UA. FactoryNebula reads those variables and puts them on the bus and in the database. With the browser you navigate the server and add values with a click.

OPC UA · live
Example
Machining centre 02 · Mode
AUTO
Machining centre 02 · Status
RUNNING
What it does
Every machine arrives on the bus in the same way. Everything built on top of it, such as dashboards, OEE and workflows, therefore works for every brand.
Browse the server to the right variable and add it. You don’t need to know the NodeId.
Without security, or with certificates (Basic256Sha256, SignAndEncrypt), with or without a username.
Optionally the connector publishes a normalised status per machine: RUNNING, IDLE, STOPPED or ALARM.
For each group of variables you choose how often it is read and where it goes.
On the machine side
For reading, nothing needs to change in the machine program. You arrange this in advance.
Specifications
Then the server doesn’t trust the gateway’s certificate yet. Accept the gateway’s client certificate on the OPC UA server.
After a server update the NodeId sometimes no longer exists. Look up the variable again with the browser.
In its endpoint the server sometimes returns a hostname that the gateway doesn’t know. Have that hostname resolved on the gateway, or use the IP address in the server configuration.
Further reading
Two widely used protocols for getting data out of machines, and when you will come across each. Plus: what if a machine has neither?
Why every machine should get a fixed place in one structure for the whole factory, and why that makes integrations so much simpler.
Connecting machines brings data closer to decisions, but it requires care. Three points of attention: OT/IT separation, data ownership and NIS2.
More connectors
Read S7-300, S7-400, S7-1200 and S7-1500, continuously or on a trigger.
Modbus TCP and RTU: drives, energy meters, simple PLCs and sensors.
Read ControlLogix and CompactLogix by tag name, with tag browser.
Status, program, part counter and alarms of FANUC controls, with network scan.
iTNC 530, TNC 640 and related: status, program, tool, axes and PLC values.
Every read of a SICK Lector on the bus: QR, DataMatrix and barcodes.
Status of Linx coding printers, and loading messages such as lot number or date.
In a personal demo we show how a machine gets into FactoryNebula, and what is needed on the machine side.